CORVUS SYSTEMS, INC. TRANSPORTER MODEL 8010-10440 NIC Type OmniNet (proprietary) Network Transfer Rate Unidentified Data Bus 8-bit ISA Topology Linear Bus Wire Type Shielded/Unshielded twisted pair Boot ROM Available [Image] CONNECTIONS Function Label Unshielded or shielded twisted pair CN1 via 1/8" plug USER CONFIGURABLE SETTINGS Setting Label Position » Factory configured - do not alter E2 Pins 1 & 2 closed NODE ADDRESS Setting U14/1 U14/2 U14/3 U14/4 U14/5 U14/6 0 On On On On On On 1 Off On On On On On 2 On Off On On On On 3 Off Off On On On On 4 On On Off On On On 59 Off Off On Off Off Off 60 On On Off Off Off Off 61 Off On Off Off Off Off 62 On Off Off Off Off Off 63 Off Off Off Off Off Off Note: A total of 64 node address settings are available. The switches are a binary representation of the decimal node addresses. U14/6 is the Most Significant Bit and switch U14/1 is the Least Significant Bit. The switches have the following decimal values: U14/6=32, U14/5=16, U14/4=8, U14/3=4, U14/2=2, U14/1=1. Turn off the switches and add the values of the switches that are off to obtain the correct node ID. (Off=1, On=0) BIAS SELECTION Setting U14/7 U14/8 Normal Off Off Biased On On Note:Only one machine per network should be set to biased. BASE I/O ADDRESS Setting E1/A E1/B E1/C E1/D 240h Closed Open Open Open » 248h Open Closed Open Open 250h Open Open Closed Open 258h Open Open Open Closed Note:E1 is a set of solder contacts. To change the address, you must cut the trace on E1/C andhard-wire a jumper with a soldering gun.